2015-03-09 10:10:09 – Service Started ------------------------------------- 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'Debugger' -> IsAttached: False. 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'AssemblyProperties' -> FullName: "OpcLabs.BaseLib, Version=5.32.1063.1, Culture=neutral, PublicKeyToken=6faddca41dacb409", Location: "C:\Program Files (x86)\ContelITS\CI_OpcInterface\OpcLabs.BaseLib.dll", GlobalAssemblyCache: False. 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'AssemblyAttributes' -> AssemblyConfiguration: "Release". 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'Clr' -> Version: '4.0.30319.17929', PtrSize: 8. 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'Process' -> Is64BitProcess: True, CurrentDirectory: "C:\Windows\system32", Id: 11788. 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'User' -> Name: "SYSTEM", DomainName: "D_STRAUSS", Interactive: False. 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'OSConfiguration' -> MachineName: "MESAPPPRD", SystemPageSize: 4096. 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'OperatingSystem' -> VersionString: "Microsoft Windows NT 6.1.7601 Service Pack 1". 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'Environment' -> Is64BitOperatingSystem: True, SystemDirectory: "C:\Windows\system32". 2015-03-09 10:10:11 – Information: OPC-UA engine application info 'Computer' -> ProcessorCount: 2. 2015-03-09 10:10:11 – Information: The OPC-UA engine is connecting to the underlying subsystems. 2015-03-09 10:10:11 – Warning: OPC-UA engine SDK configuration provider "OpcLabs.EasyOpc.UA.Toolkit.AppConfigSdkConfigurationProvider" failed OpcLabs.EasyOpc.UA.UAServiceException: OPC-UA service result - Could not load configuration file. ---- SERVICE RESULT ---- StatusCode: {BadConfigurationError} = 0x80890000 (2156462080) Description: Could not load configuration file. 2015-03-09 10:10:11 – Warning: OPC-UA engine SDK configuration successfully provided by "OpcLabs.EasyOpc.UA.Toolkit.InternalSdkConfigurationProvider". 2015-03-09 10:10:11 – Information: The OPC-UA engine has determined the client certificate parameters as listed below. SubjectName: CN=CI_OpcInterface, DC=MESappprd ApplicationName: CI_OpcInterface ApplicationUri: urn:MESappprd:CI_OpcInterface:1.0.0.0:neutral:null ProductUri: urn:literal:string:CI_OpcInterface 2015-03-09 10:10:11 – Information: The OPC-UA engine has successfully connected to the underlying subsystems. 2015-03-09 10:10:12 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 10:10:13 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 10:10:13 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 10:10:13 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 10:10:13 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 10:10:13 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 10:10:13 – Warning: The server certificate failed validation with error code 0x801A0000 while establishing OPC-UA client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". BadCertificateUntrusted 'Certificate is not trusted. SubjectName: CN=KEPServerEX/UA Server, O=Microsoft, C=IL, DC=MESappdev.str.corp.strauss.co.il IssuerName: CN=KEPServerEX/UA Server, O=Microsoft, C=IL, DC=MESappdev.str.corp.strauss.co.il' 2015-03-09 10:10:13 – SuccessAudit: The server certificate has been accepted for the OPC-UA client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" by a fallback method. Certificate information: [Subject] CN=KEPServerEX/UA Server, O=Microsoft, C=IL, DC=MESappdev.str.corp.strauss.co.il [Issuer] CN=KEPServerEX/UA Server, O=Microsoft, C=IL, DC=MESappdev.str.corp.strauss.co.il [Serial Number] A9D69820 [Not Before] 22/08/2011 09:18:00 [Not After] 19/08/2021 09:18:00 [Thumbprint] DD0227F830B4450287515C91964CDA29392D79CF 2015-03-09 10:10:13 – Information: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 10:10:13 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 10:10:13 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 10:10:13 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 10:10:20 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has reported a subscription acknowledgement error with code 0x807A0000 for subscription Id 257 and sequence number 1. Further subscription acknowledgement errors with this code on this session will not be logged. Operation result: BadSequenceNumberUnknown. 2015-03-09 10:11:59 – Warning: The OPC-UA subscription publishing has stopped on the client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". Further such errors on this session will not be logged. 2015-03-09 10:26:53 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has reported a subscription acknowledgement error with code 0x80280000 for subscription Id 261 and sequence number 3. Further subscription acknowledgement errors with this code on this session will not be logged. Operation result: BadSubscriptionIdInvalid. 2015-03-09 11:00:45 – Information: The OPC-UA client session is disconnecting from endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:00:45 – Information: The OPC-UA client session has disconnected from endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:00:45 – Information: The OPC-UA client session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" failed at tick -272901440 and will retry in 10000 milliseconds. 2015-03-09 11:00:45 – Warning: The status subscription for an OPC-UA session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" is in failure. Further such warnings on this session will not be logged. OPC-UA service result - An error specific to OPC-UA service occurred. ---- SERVICE RESULT ---- StatusCode: {BadNoCommunication} = 0x80310000 (2150694912) Description: Server not responding to keep alive requests. 2015-03-09 11:00:45 – Information: The OPC-UA client session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" failed at tick -272901440 and will retry in 10000 milliseconds. 2015-03-09 11:00:45 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:00:45 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 11:00:45 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 11:00:45 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 11:00:45 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 11:00:45 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 11:00:45 – Information: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 11:00:45 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 11:00:45 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:00:45 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 11:00:50 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has reported a subscription acknowledgement error with code 0x807A0000 for subscription Id 278 and sequence number 1. Further subscription acknowledgement errors with this code on this session will not be logged. Operation result: BadSequenceNumberUnknown. 2015-03-09 11:01:50 – Warning: The OPC-UA subscription publishing has stopped on the client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". Further such errors on this session will not be logged. 2015-03-09 11:02:30 – Information: The OPC-UA client session is disconnecting from endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:02:31 – Information: The OPC-UA client session has disconnected from endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:03:31 – Information: The OPC-UA client session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" failed at tick -272734753 and will retry in 10000 milliseconds. 2015-03-09 11:03:31 – Warning: The status subscription for an OPC-UA session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" is in failure. Further such warnings on this session will not be logged. OPC-UA service result - An error specific to OPC-UA service occurred. ---- SERVICE RESULT ---- StatusCode: {BadNoCommunication} = 0x80310000 (2150694912) Description: Server not responding to keep alive requests. 2015-03-09 11:03:31 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:03:32 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 11:03:32 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 11:03:32 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 11:03:32 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 11:03:32 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 11:03:32 – Information: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 11:03:32 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 11:03:32 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:03:32 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 11:03:41 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has reported a subscription acknowledgement error with code 0x807A0000 for subscription Id 280 and sequence number 1. Further subscription acknowledgement errors with this code on this session will not be logged. Operation result: BadSequenceNumberUnknown. 2015-03-09 11:07:05 – Warning: The OPC-UA subscription publishing has stopped on the client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". Further such errors on this session will not be logged. 2015-03-09 11:19:20 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:19:20 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 11:19:20 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 11:19:20 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 11:19:20 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 11:19:20 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 11:19:20 – Information: The OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 11:19:20 – Warning: The OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 11:19:20 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:19:20 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 11:19:26 – Information: The OPC-UA client session is disconnecting from endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:19:26 – Information: The OPC-UA client session has disconnected from endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:19:36 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:19:36 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 11:19:36 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 11:19:36 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 11:19:36 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 11:19:36 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 11:19:36 – Information: The OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 11:19:36 – Warning: The OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 11:19:36 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:19:36 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 11:19:42 – Information: The OPC-UA client session is disconnecting from endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:19:42 – Information: The OPC-UA client session has disconnected from endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:23:43 – Service Started ------------------------------------- 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'Debugger' -> IsAttached: False. 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'AssemblyProperties' -> FullName: "OpcLabs.BaseLib, Version=5.32.1063.1, Culture=neutral, PublicKeyToken=6faddca41dacb409", Location: "C:\Program Files (x86)\ContelITS\CI_OpcInterface\OpcLabs.BaseLib.dll", GlobalAssemblyCache: False. 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'AssemblyAttributes' -> AssemblyConfiguration: "Release". 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'Clr' -> Version: '4.0.30319.17929', PtrSize: 8. 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'Process' -> Is64BitProcess: True, CurrentDirectory: "C:\Windows\system32", Id: 15488. 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'User' -> Name: "SYSTEM", DomainName: "D_STRAUSS", Interactive: False. 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'OSConfiguration' -> MachineName: "MESAPPPRD", SystemPageSize: 4096. 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'OperatingSystem' -> VersionString: "Microsoft Windows NT 6.1.7601 Service Pack 1". 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'Environment' -> Is64BitOperatingSystem: True, SystemDirectory: "C:\Windows\system32". 2015-03-09 11:23:43 – Information: OPC-UA engine application info 'Computer' -> ProcessorCount: 2. 2015-03-09 11:23:43 – Information: The OPC-UA engine is connecting to the underlying subsystems. 2015-03-09 11:23:43 – Warning: OPC-UA engine SDK configuration provider "OpcLabs.EasyOpc.UA.Toolkit.AppConfigSdkConfigurationProvider" failed OpcLabs.EasyOpc.UA.UAServiceException: OPC-UA service result - Could not load configuration file. ---- SERVICE RESULT ---- StatusCode: {BadConfigurationError} = 0x80890000 (2156462080) Description: Could not load configuration file. 2015-03-09 11:23:43 – Warning: OPC-UA engine SDK configuration successfully provided by "OpcLabs.EasyOpc.UA.Toolkit.InternalSdkConfigurationProvider". 2015-03-09 11:23:43 – Information: The OPC-UA engine has determined the client certificate parameters as listed below. SubjectName: CN=CI_OpcInterface, DC=MESappprd ApplicationName: CI_OpcInterface ApplicationUri: urn:MESappprd:CI_OpcInterface:1.0.0.0:neutral:null ProductUri: urn:literal:string:CI_OpcInterface 2015-03-09 11:23:43 – Information: The OPC-UA engine has successfully connected to the underlying subsystems. 2015-03-09 11:23:44 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:23:44 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 11:23:44 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 11:23:44 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 11:23:44 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 11:23:44 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 11:23:44 – Warning: The server certificate failed validation with error code 0x801A0000 while establishing OPC-UA client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". BadCertificateUntrusted 'Certificate is not trusted. SubjectName: CN=KEPServerEX/UA Server, O=Microsoft, C=IL, DC=MESappdev.str.corp.strauss.co.il IssuerName: CN=KEPServerEX/UA Server, O=Microsoft, C=IL, DC=MESappdev.str.corp.strauss.co.il' 2015-03-09 11:23:44 – SuccessAudit: The server certificate has been accepted for the OPC-UA client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" by a fallback method. Certificate information: [Subject] CN=KEPServerEX/UA Server, O=Microsoft, C=IL, DC=MESappdev.str.corp.strauss.co.il [Issuer] CN=KEPServerEX/UA Server, O=Microsoft, C=IL, DC=MESappdev.str.corp.strauss.co.il [Serial Number] A9D69820 [Not Before] 22/08/2011 09:18:00 [Not After] 19/08/2021 09:18:00 [Thumbprint] DD0227F830B4450287515C91964CDA29392D79CF 2015-03-09 11:23:44 – Information: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 11:23:44 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 11:23:45 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:23:45 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 11:23:51 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has reported a subscription acknowledgement error with code 0x807A0000 for subscription Id 287 and sequence number 1. Further subscription acknowledgement errors with this code on this session will not be logged. Operation result: BadSequenceNumberUnknown. 2015-03-09 11:24:48 – Warning: The OPC-UA subscription publishing has stopped on the client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". Further such errors on this session will not be logged. 2015-03-09 11:26:22 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has reported a subscription acknowledgement error with code 0x80280000 for subscription Id 287 and sequence number 3. Further subscription acknowledgement errors with this code on this session will not be logged. Operation result: BadSubscriptionIdInvalid. 2015-03-09 11:32:41 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:32:41 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 11:32:41 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 11:32:41 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 11:32:41 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 11:32:41 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 11:32:41 – Information: The OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 11:32:41 – Warning: The OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 11:32:41 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:32:41 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 11:32:47 – Information: The OPC-UA client session is disconnecting from endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:32:47 – Information: The OPC-UA client session has disconnected from endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:34:18 – Information: The OPC-UA client session is disconnecting from endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:34:18 – Information: The OPC-UA client session has disconnected from endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:34:18 – Information: The OPC-UA client session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" failed at tick -270887498 and will retry in 10000 milliseconds. 2015-03-09 11:34:18 – Warning: The status subscription for an OPC-UA session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" is in failure. Further such warnings on this session will not be logged. OPC-UA service result - An error specific to OPC-UA service occurred. ---- SERVICE RESULT ---- StatusCode: {BadNoCommunication} = 0x80310000 (2150694912) Description: Server not responding to keep alive requests. 2015-03-09 11:34:18 – Information: The OPC-UA client session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" failed at tick -270887498 and will retry in 10000 milliseconds. 2015-03-09 11:34:18 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:34:19 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 11:34:19 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 11:34:19 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 11:34:19 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 11:34:19 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 11:34:20 – Information: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 11:34:20 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 11:34:20 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 11:34:36 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 11:34:43 – Warning: The OPC-UA server on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" has reported a subscription acknowledgement error with code 0x807A0000 for subscription Id 291 and sequence number 1. Further subscription acknowledgement errors with this code on this session will not be logged. Operation result: BadSequenceNumberUnknown. 2015-03-09 11:36:11 – Warning: The OPC-UA subscription publishing has stopped on the client session to endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". Further such errors on this session will not be logged. 2015-03-09 12:15:48 – Information: The OPC-UA client session is connecting to endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 12:15:48 – Information: OPC-UA endpoint selection on discovery URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" candidate report (8 entries) follows. [0:Winner(0), 1:EligibleNotAccepted(0), 2:EligibleNotAccepted(0), 3:EligibleNotAccepted(0), 4:EligibleNotAccepted(0), 5:EligibleNotAccepted(0), 6:EligibleNotAccepted(0), 7:EligibleNotAccepted(0)]. 2015-03-09 12:15:48 – Warning: The OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2015-03-09 12:15:48 – Warning: The preference for endpoint selection was not to use security, but the OPC-UA server endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", selected using discovery on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", has message security mode 'Sign'. This happens when no unsecured endpoints are available and eligible for selection. 2015-03-09 12:15:48 – Information: An OPC-UA endpoint has been selected for discovery URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" with following parameters: Endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320", message security mode 'Sign', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#Basic128Rsa15", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2015-03-09 12:15:48 – Information: OPC-UA user token selection on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" candidate report (2 entries) follows. [0:Winner(""), 1:ValidNotEligible(NotApplicable("http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-username-token-profile-1.0"))]. 2015-03-09 12:15:48 – Information: The OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" returned an empty list of software certificates. 2015-03-09 12:15:48 – Warning: The OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" did not return a valid software certificate for product URI "??" listed in server endpoints. The server returned 0 software certificate(s) in total. 2015-03-09 12:15:48 – Information: The OPC-UA client session has successfully connected to endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 12:15:48 – Information: When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2015-03-09 12:15:53 – Information: The OPC-UA client session is disconnecting from endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 12:15:53 – Information: The OPC-UA client session has disconnected from endpoint URL "opc.tcp://MESappprd.str.corp.strauss.co.il:49320". 2015-03-09 12:32:08 – Information: The OPC-UA client session is disconnecting from endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 12:32:08 – Information: The OPC-UA client session has disconnected from endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320". 2015-03-09 12:32:08 – Information: The OPC-UA client session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" failed at tick -267419081 and will retry in 10000 milliseconds. 2015-03-09 12:32:08 – Warning: The status subscription for an OPC-UA session on endpoint URL "opc.tcp://mesappprd.str.corp.strauss.co.il:49320" is in failure. Further such warnings on this session will not be logged. OPC-UA service result - An error specific to OPC-UA service occurred. ---- SERVICE RESULT ---- StatusCode: {BadNoCommunication} = 0x80310000 (2150694912) Description: Server not responding to keep alive requests.