2016-07-13 08:13:26,135 [10] INFO ++ Starting .... 2016-07-13 08:13:27,508 [18] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'AssemblyAttributes' -> AssemblyConfiguration: "Release". 2016-07-13 08:13:27,508 [18] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'AppDomain' -> Id: 1. 2016-07-13 08:13:27,508 [16] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'Debugger' -> IsAttached: True. 2016-07-13 08:13:27,508 [18] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'Clr' -> Version: '4.0.30319.42000', PtrSize: 4. 2016-07-13 08:13:27,508 [17] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'AssemblyProperties' -> FullName: "OpcLabs.BaseLib, Version=5.40.287.1, Culture=neutral, PublicKeyToken=6faddca41dacb409", Location: "D:\Projects\Scada\HMI\Main HMI OPC Upgrade test 2\ThalloLine\HMI\bin\Release\OpcLabs.BaseLib.dll", GlobalAssemblyCache: False. 2016-07-13 08:13:27,508 [17] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'OSConfiguration' -> MachineName: "NB-ERIKVANDERVE", SystemPageSize: 4096. 2016-07-13 08:13:27,508 [17] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'OperatingSystem' -> VersionString: "Microsoft Windows NT 6.1.7601 Service Pack 1". 2016-07-13 08:13:27,508 [17] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'Environment' -> Is64BitOperatingSystem: True, SystemDirectory: "C:\Windows\system32". 2016-07-13 08:13:27,508 [17] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'Computer' -> ProcessorCount: 4. 2016-07-13 08:13:27,508 [16] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'Process' -> Is64BitProcess: False, CurrentDirectory: "D:\Projects\Scada\HMI\Main HMI OPC Upgrade test 2\ThalloLine\HMI\bin\Release", Id: 2188. 2016-07-13 08:13:27,508 [18] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine application info 'User' -> Name: "erik_vanderveen", DomainName: "DGPS", Interactive: True. 2016-07-13 08:13:27,508 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA engine is connecting to the underlying subsystems. 2016-07-13 08:13:27,820 [17] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA engine SDK configuration successfully provided by "OpcLabs.EasyOpc.UA.Toolkit.InternalSdkConfigurationProvider". 2016-07-13 08:13:27,820 [16] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA engine has determined the client certificate parameters as listed below. SubjectName: Thallo HMI ApplicationName: Thallo HMI ApplicationUri: urn:NB-ErikvanderVe:Thallo_HMI:1.0.6038.14449:neutral:null ProductUri: urn:literal:string:Thallo%20HMI 2016-07-13 08:13:28,585 [16] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA engine has successfully connected to the underlying subsystems. 2016-07-13 08:13:38,849 [18] INFO EasyUAClient: OPCLabs-EasyUAClient, Licensing for EasyUAClient component started, license serial number 1111111120, issuer name "OPC Labs", subject name "*". 2016-07-13 08:13:38,943 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 1 is connecting to endpoint URL "opc.tcp://172.17.1.1:4840". 2016-07-13 08:13:39,426 [27] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA endpoint selection on discovery URL "opc.tcp://172.17.1.1:4840" candidate report (1 entries) follows. [0:Winner(1000+0)]. 2016-07-13 08:13:39,426 [18] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server endpoint URL "opc.tcp://172.17.1.1:4840" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#None" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://172.17.1.1:4840", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2016-07-13 08:13:39,442 [27] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 1 has selected an OPC-UA endpoint for discovery URL "opc.tcp://172.17.1.1:4840" with following parameters: Endpoint URL "opc.tcp://172.17.1.1:4840", message security mode 'None', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#None", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2016-07-13 08:13:39,442 [27] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 1 user token selection on endpoint URL "opc.tcp://172.17.1.1:4840" candidate report (1 entries) follows. [0:Winner("")]. 2016-07-13 08:13:39,504 [27] WARN EasyUAClient: OPCLabs-UAEngine, The server certificate failed validation with error code 0x801A0000 while establishing OPC-UA client session to endpoint URL "opc.tcp://172.17.1.1:4840". BadCertificateUntrusted 'Certificate is not trusted. SubjectName: CN=IndraControl, OU=DC-IA, O=Bosch Rexroth AG, L=Erbach, S=Hesse, C=DE IssuerName: CN=IndraControl, OU=DC-IA, O=Bosch Rexroth AG, L=Erbach, S=Hesse, C=DE' 2016-07-13 08:13:39,551 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.1:4840" returned an empty list of software certificates. 2016-07-13 08:13:39,551 [27] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.1:4840" did not return a valid software certificate for product URI "http://www.boschrexroth.com/country_units/europe/germany/de/products/index.jsp" listed in server endpoints. The server returned 0 software certificate(s) in total. 2016-07-13 08:13:39,551 [27] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.1:4840" returned an empty server signature. 2016-07-13 08:13:39,567 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 1 has successfully connected to endpoint URL "opc.tcp://172.17.1.1:4840". The server-assigned session Id is "ns=1;i=21789". 2016-07-13 08:13:39,582 [17] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA publishing counts (either the keep-alive count, or the lifetime count, or both) had to be adjusted on the client session with connect sequence number 1 to endpoint URL "opc.tcp://172.17.1.1:4840". Old/new/maximum keep-alive count: 34560/34560/4294967295. Old/new/maximum lifetime count: 103680/34560/4294967295. 2016-07-13 08:13:39,598 [18] INFO EasyUAClient: OPCLabs-UAEngine, The requested maximum keep-alive count of 34560 has been revised by the OPC-UA server subscription ID 21796 on endpoint URL "opc.tcp://172.17.1.1:4840" to a different value, 4. Further such warnings on this session will not be logged. 2016-07-13 08:13:39,598 [18] INFO EasyUAClient: OPCLabs-UAEngine, The requested maximum keep-alive count of 34560 has been revised by the OPC-UA server subscription ID 21796 on endpoint URL "opc.tcp://172.17.1.1:4840" to 4, which is below the tolerance range. The subscription will still be used. Further such warnings on this session will not be logged. 2016-07-13 08:13:39,598 [18] INFO EasyUAClient: OPCLabs-UAEngine, The requested lifetime count of 103680 has been revised by the OPC-UA server subscription ID 21796 on endpoint URL "opc.tcp://172.17.1.1:4840" to a different value, 12. Further such warnings on this session will not be logged. 2016-07-13 08:13:39,598 [18] INFO EasyUAClient: OPCLabs-UAEngine, The requested lifetime count of 103680 has been revised by the OPC-UA server subscription ID 21796 on endpoint URL "opc.tcp://172.17.1.1:4840" to 12, which is below the tolerance range. The subscription will still be used. Further such warnings on this session will not be logged. 2016-07-13 08:13:39,707 [18] INFO EasyUAClient: OPCLabs-UAEngine, When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://172.17.1.1:4840" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2016-07-13 08:13:40,160 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 2 is connecting to endpoint URL "opc.tcp://172.17.1.2:4840". 2016-07-13 08:13:40,160 [18] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA endpoint selection on discovery URL "opc.tcp://172.17.1.2:4840" candidate report (1 entries) follows. [0:Winner(1000+0)]. 2016-07-13 08:13:40,160 [18] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server endpoint URL "opc.tcp://172.17.1.2:4840" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#None" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://172.17.1.2:4840", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2016-07-13 08:13:40,160 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 2 has selected an OPC-UA endpoint for discovery URL "opc.tcp://172.17.1.2:4840" with following parameters: Endpoint URL "opc.tcp://172.17.1.2:4840", message security mode 'None', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#None", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2016-07-13 08:13:40,160 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 2 user token selection on endpoint URL "opc.tcp://172.17.1.2:4840" candidate report (1 entries) follows. [0:Winner("")]. 2016-07-13 08:13:40,175 [27] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.2:4840" returned an empty list of software certificates. 2016-07-13 08:13:40,175 [27] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.2:4840" did not return a valid software certificate for product URI "http://www.boschrexroth.com/country_units/europe/germany/de/products/index.jsp" listed in server endpoints. The server returned 0 software certificate(s) in total. 2016-07-13 08:13:40,175 [27] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.2:4840" returned an empty server signature. 2016-07-13 08:13:40,175 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 2 has successfully connected to endpoint URL "opc.tcp://172.17.1.2:4840". The server-assigned session Id is "ns=1;i=24656". 2016-07-13 08:13:40,175 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA publishing counts (either the keep-alive count, or the lifetime count, or both) had to be adjusted on the client session with connect sequence number 2 to endpoint URL "opc.tcp://172.17.1.2:4840". Old/new/maximum keep-alive count: 34560/34560/4294967295. Old/new/maximum lifetime count: 103680/34560/4294967295. 2016-07-13 08:13:40,191 [18] INFO EasyUAClient: OPCLabs-UAEngine, The requested maximum keep-alive count of 34560 has been revised by the OPC-UA server subscription ID 24664 on endpoint URL "opc.tcp://172.17.1.2:4840" to a different value, 4. Further such warnings on this session will not be logged. 2016-07-13 08:13:40,191 [18] INFO EasyUAClient: OPCLabs-UAEngine, The requested maximum keep-alive count of 34560 has been revised by the OPC-UA server subscription ID 24664 on endpoint URL "opc.tcp://172.17.1.2:4840" to 4, which is below the tolerance range. The subscription will still be used. Further such warnings on this session will not be logged. 2016-07-13 08:13:40,191 [18] INFO EasyUAClient: OPCLabs-UAEngine, The requested lifetime count of 103680 has been revised by the OPC-UA server subscription ID 24664 on endpoint URL "opc.tcp://172.17.1.2:4840" to a different value, 12. Further such warnings on this session will not be logged. 2016-07-13 08:13:40,191 [18] INFO EasyUAClient: OPCLabs-UAEngine, The requested lifetime count of 103680 has been revised by the OPC-UA server subscription ID 24664 on endpoint URL "opc.tcp://172.17.1.2:4840" to 12, which is below the tolerance range. The subscription will still be used. Further such warnings on this session will not be logged. 2016-07-13 08:13:40,222 [18] INFO EasyUAClient: OPCLabs-UAEngine, When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://172.17.1.2:4840" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2016-07-13 08:13:46,072 [17] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA publishing counts (either the keep-alive count, or the lifetime count, or both) had to be adjusted on the client session with connect sequence number 1 to endpoint URL "opc.tcp://172.17.1.1:4840". Old/new/maximum keep-alive count: 2073600/2073600/4294967295. Old/new/maximum lifetime count: 6220800/2073600/4294967295. 2016-07-13 08:13:46,696 [6] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 2 is disconnecting from endpoint URL "opc.tcp://172.17.1.2:4840". 2016-07-13 08:13:46,712 [6] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 2 has disconnected from endpoint URL "opc.tcp://172.17.1.2:4840". 2016-07-13 08:13:48,443 [25] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 3 is connecting to endpoint URL "opc.tcp://172.17.1.2:4840". 2016-07-13 08:13:48,443 [6] INFO EasyUAClient: OPCLabs-UAEngine, OPC-UA endpoint selection on discovery URL "opc.tcp://172.17.1.2:4840" candidate report (1 entries) follows. [0:Winner(1000+0)]. 2016-07-13 08:13:48,443 [16] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server endpoint URL "opc.tcp://172.17.1.2:4840" with security policy URI "http://opcfoundation.org/UA/SecurityPolicy#None" and transport policy URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary", selected using discovery on endpoint URL "opc.tcp://172.17.1.2:4840", has zero security level. Using this endpoint is not recommended and is only supported for backward compatibility. This happens when no other endpoints are available and eligible for selection. 2016-07-13 08:13:48,443 [16] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 3 has selected an OPC-UA endpoint for discovery URL "opc.tcp://172.17.1.2:4840" with following parameters: Endpoint URL "opc.tcp://172.17.1.2:4840", message security mode 'None', security policy URI "http://opcfoundation.org/UA/SecurityPolicy#None", transport profile URI "http://opcfoundation.org/UA-Profile/Transport/uatcp-uasc-uabinary". 2016-07-13 08:13:48,443 [18] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 3 user token selection on endpoint URL "opc.tcp://172.17.1.2:4840" candidate report (1 entries) follows. [0:Winner("")]. 2016-07-13 08:13:48,459 [17] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.2:4840" returned an empty list of software certificates. 2016-07-13 08:13:48,459 [6] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.2:4840" did not return a valid software certificate for product URI "http://www.boschrexroth.com/country_units/europe/germany/de/products/index.jsp" listed in server endpoints. The server returned 0 software certificate(s) in total. 2016-07-13 08:13:48,459 [16] WARN EasyUAClient: OPCLabs-UAEngine, The OPC-UA server on endpoint URL "opc.tcp://172.17.1.2:4840" returned an empty server signature. 2016-07-13 08:13:48,459 [29] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA client session with connect sequence number 3 has successfully connected to endpoint URL "opc.tcp://172.17.1.2:4840". The server-assigned session Id is "ns=1;i=24657". 2016-07-13 08:13:48,459 [16] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA publishing counts (either the keep-alive count, or the lifetime count, or both) had to be adjusted on the client session with connect sequence number 3 to endpoint URL "opc.tcp://172.17.1.2:4840". Old/new/maximum keep-alive count: 34560/34560/4294967295. Old/new/maximum lifetime count: 103680/34560/4294967295. 2016-07-13 08:13:48,459 [6] INFO EasyUAClient: OPCLabs-UAEngine, The requested maximum keep-alive count of 34560 has been revised by the OPC-UA server subscription ID 24665 on endpoint URL "opc.tcp://172.17.1.2:4840" to a different value, 4. Further such warnings on this session will not be logged. 2016-07-13 08:13:48,474 [6] INFO EasyUAClient: OPCLabs-UAEngine, The requested lifetime count of 103680 has been revised by the OPC-UA server subscription ID 24665 on endpoint URL "opc.tcp://172.17.1.2:4840" to 12, which is below the tolerance range. The subscription will still be used. Further such warnings on this session will not be logged. 2016-07-13 08:13:48,459 [29] INFO EasyUAClient: OPCLabs-UAEngine, The requested lifetime count of 103680 has been revised by the OPC-UA server subscription ID 24665 on endpoint URL "opc.tcp://172.17.1.2:4840" to a different value, 12. Further such warnings on this session will not be logged. 2016-07-13 08:13:48,459 [17] INFO EasyUAClient: OPCLabs-UAEngine, The requested maximum keep-alive count of 34560 has been revised by the OPC-UA server subscription ID 24665 on endpoint URL "opc.tcp://172.17.1.2:4840" to 4, which is below the tolerance range. The subscription will still be used. Further such warnings on this session will not be logged. 2016-07-13 08:13:48,521 [26] INFO EasyUAClient: OPCLabs-UAEngine, When creating or modifying a monitored item, the OPC-UA server on endpoint URL "opc.tcp://172.17.1.2:4840" has revised the sampling interval to 5000 milliseconds; the requested sampling interval was 15000 milliseconds. Further such warnings on this session will not be logged. 2016-07-13 08:13:48,521 [26] INFO EasyUAClient: OPCLabs-UAEngine, The OPC-UA publishing counts (either the keep-alive count, or the lifetime count, or both) had to be adjusted on the client session with connect sequence number 3 to endpoint URL "opc.tcp://172.17.1.2:4840". Old/new/maximum keep-alive count: 2073600/2073600/4294967295. Old/new/maximum lifetime count: 6220800/2073600/4294967295. 2016-07-13 08:13:53,841 [10] ERROR HMI.MainFrame.AlarmHeader.SubscribeAlarmService: Error occurred: Could not connect to net.tcp://localhost:40123/AlarmService/. The connection attempt lasted for a time span of 00:00:02.0123742. TCP error code 10061: No connection could be made because the target machine actively refused it 127.0.0.1:40123. 2016-07-13 08:13:56,851 [10] INFO -- Exiting ....